IZINDABA

I-N3 HV Hybrid Inverter Parallel Connection Isingeniso

Ingemuva

I-RENAC N3 HV Series iyi-inverter yokugcina amandla kagesi enezigaba ezintathu eziphezulu. Iqukethe 5kW, 6kW, 8kW, 10kW izinhlobo ezine zemikhiqizo yamandla. Ezimweni zokusetshenziswa kwendlu enkulu noma ezimbonini ezincane nezohwebo, amandla amakhulu angu-10kW angase angahlangabezani nezidingo zamakhasimende.

Singasebenzisa ama-inverter amaningi ukuze sakhe isistimu ehambisanayo yokwandisa umthamo.

 

Ukuxhumana okuhambisanayo

I-inverter inikeza umsebenzi wokuxhuma okufanayo. I-inverter eyodwa izosethwa njenge-“Master

inverter” ukuze ulawule amanye ama-“Slave inverters” ohlelweni. Inombolo enkulu yama-inverter ahambisanayo limi kanje:

Inombolo enkulu yama-inverter ahambisanayo

I-N3线路图

 

Izidingo zokuxhumeka okufanayo

• Wonke ama-inverters kufanele abe yinguqulo yesofthiwe efanayo.

• Wonke ama-inverters kufanele abe namandla afanayo.

• Wonke amabhethri axhunywe kuma-inverters kufanele abe nemininingwane efanayo.

 

Umdwebo woxhumano oluhambisanayo

I-N3线路图

 

 

 

I-N3线路图

 

 

I-N3线路图

 

● Uxhumano oluhambisanayo ngaphandle kwe-EPS Parallel Box.

»Sebenzisa izintambo zenethiwekhi ezijwayelekile zoxhumano lwe-Master-Slave inverter.

»Isiguquli esiyinhloko I-Parallel port-2 ixhuma ku-Slave 1 inverter Parallel port-1.

» Isigqila esingu-1 inverter I-Parallel port-2 ixhuma ku-Slave 2 inverter Parallel port-1.

» Amanye ama-inverters axhunywe ngendlela efanayo.

» Imitha ehlakaniphile ixhuma kutheminali ye-METER ye-inverter eyinhloko.

» Xhuma ukumelana netheminali (kuphakheji yensiza ye-inverter) endaweni engenalutho ehambisanayo yesishintshi sokugcina.

 

● Ukuxhumana okufanayo ne-EPS Parallel Box.

»Sebenzisa izintambo zenethiwekhi ezijwayelekile zoxhumano lwe-Master-Slave inverter.

» I-master inverter I-Parallel port-1 ixhuma kutheminali ye-COM ye-EPS Parallel Box.

»Isiguquli esiyinhloko I-Parallel port-2 ixhuma ku-Slave 1 inverter Parallel port-1.

» Isigqila esingu-1 inverter I-Parallel port-2 ixhuma ku-Slave 2 inverter Parallel port-1.

» Amanye ama-inverters axhunywe ngendlela efanayo.

» Imitha ehlakaniphile ixhuma kutheminali ye-METER ye-inverter eyinhloko.

» Xhuma ukumelana netheminali (kuphakheji yensiza ye-inverter) endaweni engenalutho ehambisanayo yesishintshi sokugcina.

» Amachweba we-EPS1~EPS5 e-EPS Parallel Box axhuma imbobo ye-EPS yesiguquli ngasinye.

» Imbobo ye-GRID ye-EPS Parallel Box ixhuma ebhandeni bese imbobo ye-LOAD ixhuma imithwalo eyisipele.

 

Izindlela zokusebenza

Kunezindlela ezintathu zokusebenza ohlelweni oluhambisanayo, futhi ukuvuma kwakho izindlela zokusebenza ezihlukile ze-inverter kuzokusiza uqonde kangcono uhlelo oluhambisanayo.

● Imodi Eyodwa: Asikho isiguquli esisethwe njenge-“Master”. Wonke ama-inverter akumodi eyodwa ohlelweni.

● I-Master Mode: Uma inverter eyodwa isethwe njenge-“Master,” lesi siguquli singena kumodi eyinhloko. Imodi eyinhloko ingashintshwa

kumodi eyodwa ngokusetha kwe-LCD.

● I-Slave Mode: Uma isiguquli esishintshayo esisodwa sisethwa njengokuthi “Inkosi,” wonke amanye ama-inverter azongena kumodi yesigqila ngokuzenzakalelayo. Imodi yesigqila ayikwazi ukushintshwa kwezinye izindlela ngezilungiselelo ze-LCD.

 

Izilungiselelo ze-LCD

Njengoba kukhonjisiwe ngezansi, abasebenzisi kufanele baguqule isixhumi esibonakalayo sokusebenza sibe "Okuthuthukisiwe*". Cindezela inkinobho ethi phezulu noma phansi ukuze usethe imodi yokusebenza ehambisanayo. Cindezela okuthi 'KULUNGILE' ukuze uqinisekise.

I-N3线路图